  data sheet pxc arrester at places such as water purification plants, sewage treat- ment plants and dams, there are often cases where instru- ments are damaged due to lightning. this arrester is used for protecting transmitters and receiv- ing instruments from surge voltage induced in transmission lines due to lightning etc. two types of arresters, field- mount type and panel-mount type, are available. the arrester, using fujl's z-trap, offers high performance and reliability, and is optimum for protecting semiconduc- tor circuits in instruments from surges. 1. used as the arrester element is the z-trap, which was developed at fujl's central research laboratory and is al- ready being widely used in products. the z-trap is a gapless arrester made from a sintered body which con- sists mainly of zinc oxide, and offers the following re- markable features. an excellent voltage limiting characteristic. a large surge absorption capacity despite its small size. can absorb rapidly pulsating surge because of its fast response. voltage and current characteristics are symmetrical, so surges of both positive and negative polarity are equally absorbed. stable against repetitive surge. high reliability. 2. performance is boosted by adding secondary and tertiary protective circuits made up of resistors and zener diodes as back-up circuit elements together with the z-trap. this provides excellent protection for semiconductors. 3. this is the panel-mount type (pxc) for receiving instru- ment protection. the panel-mount type can be wired systematically at the bottom of the instrument panel together with external wiring and junction terminal board. 4. being an exclusive arrester for fuji instruments the anti- surge characteristic of the system instruments and the excellent protection afforded by the arrester combine to allow utilizing the system with no worry whatever. the arrester can also be used with 4 to 20ma signal cir- cuits of other manufacturers instruments. specifications construction: features panel-mount type (pxc) housing synthetic resin, junction terminal strip structure arrester element fuji-z trap secondary protective cct. resistors, zener diodes tertiary protective cct. zener diodes working voltage: 27v dc or less (for 4 to 20ma dc) wiring method: 2 wire system internal resistance: between terminals 1?, 5?; 10 ? each total 20 ? (max. 24 ? ) discharge starting voltage: 85v dc 15% protective performance: limiting voltage; 50v or less between transmission line and ground or another transmission line (at 100a discharge) operation delay; nearly 0 s impulse discharge withstand current; 2000a with 8 x 20 s impulse wave no. of repetitive discharges; 400 times with 8 x 20 s impulse wave, 100a discharge current and 15 sec. re- peating interval. note: although this is a highly effective arrester, there are no de- vices that guarantee 100% protection against any type of light- ning. from the data collected so far it can be said that the surge voltage induced by most lightning is done in (10x200) s with crest value 5kv. in certain regions it is said to strike over a hundred times every year. it is probable that protection might be insufficient against impulses generated due to high volt- ages in direct lightning. error due to addition of arrester: less than 0.1% grounding system: grounding in coupled condition with in- strument grounding construction jis class 1 or special class 3 ambient temperature: 0 to 45 c mounting method: on copper busbar with two m4 screws external dimensions (hxwxd): 55 x 70 x 39mm mass{weight}: approx. 250g finish color: synthetic resin (black) date EDS8-5H nov. 22, 2001
pxc 1. product name and code symbol ordering information cautions on use (1) pxc has an internal resistance of 20 ? , so when both arresters are used the wiring resistance becomes 40 ? . (2) pxc is intended for signal circuits, but if an arrester for a power supply circuit is necessary, we recommend fujl's z-trap. (3) be sure to perform grounding correctly. the protected instrument and arrester should be grounded together, while keeping the grounding resistance as low as possible. (4) if the commercial frequency induced potential (common mode) to ground exceeds 35v ac, measuring error may result. perform wiring so as to avoid as much as possible any induction from power sources or the like. (5) before carrying out withstand voltage and insulation resistance tests on instruments or wiring, disconnect the arrester from the circuit. outline diagram (unit:mm) 12345678 description pxc1 00 2 0 working voltage/signal current 24v dc 4 to 20ma 2-wire system 1 code symbols panel-mount type connection diagram information in this catalog is subject to change without notice. printed in japan head office gate city ohsaki, east tower, 11-2, osaki 1-chome, shinagawa-ku, tokyo 141-0032, japan http://www.fesys.co.jp/eng instrumentation div. international sales dept. no.1, fuji-machi, hino-city, tokyo, 191-8502 japan phone: 81-42-585-6201, 6202 fax: 81-42-585-6187 http://www.fic-net.jp/eng caution on safety *before using this product, be sure to read its instruction manual in advance.


▲Up To Search▲   

 
Price & Availability of EDS8-5H

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X